Weidmüller UR20-8DIO-P-3W-DIAG
Add to cart to view estimated shipping cost.
Weidmüller UR20-8DIO-P-3W-DIAG / Lenze W560-C-3B-001 — digital input/output module, 8-channel, P-switching, 3-wire, with diagnostics, 24 V DC, PUSH IN, IP20, u-remote system, order no. 2456530000. An 8-channel bidirectional P-switching digital I/O module for the u-remote system, combining inputs and outputs in a single compact 11.5 mm wide DIN rail module. Each channel can function as either a digital input or a short-circuit-proof PNP output (up to 0.5 A per channel, 4 A per module) with individual channel-level overcurrent monitoring and line break detection on outputs. The adjustable input filter (0–40 ms), electronically limited sensor and actuator supply, and constant-current protective circuit with thermal switch-off and automatic restart ensure reliable operation across demanding machine and process automation environments. Compatible with all u-remote fieldbus head stations.
Available in stock — ships within 3 days after payment.
Product overview
| Manufacturer | Weidmüller Interface GmbH & Co. KG |
| Type | UR20-8DIO-P-3W-DIAG |
| Order number | 2456530000 |
| GTIN (EAN) | 4050118471694 |
| System reference | Lenze W560-C-3B-001 |
| Product type | Remote I/O module, IP20, Digital signals, Input, Output, 8-channel |
| Module type | Digital input module, Digital output module (bidirectional) |
| Number of channels | 8 (configurable as input or output per channel) |
| Switching type | P-switching (PNP) |
| Input type | Type 1 and Type 3, IEC 61131-2 |
| Input voltage, high | >+11 V referred to 0 V of UOUT |
| Input voltage, low | <+5 V referred to 0 V of UOUT |
| Input filter | Adjustable 0–40 ms |
| Sensor supply | ≥0.3 A per connector, electronically limited |
| Sensor/actuator connection | 2-wire, 3-wire |
| Output current per channel, max. | 500 mA |
| Output current per module, max. | 4 A |
| Actuator supply | ≤0.3 A per connector, electronically limited |
| Resistive load switching frequency | 1 kHz (min. 47 Ω) |
| Lamp load switching frequency | 10 Hz (12 W) |
| Inductive load switching frequency | 0.2 Hz (DC13) |
| Switch-off energy (inductive) | <150 mJ / channel |
| Protective circuit | Constant current with thermal switch-off and automatic restart; response time <100 µs |
| Short-circuit-proof | Yes |
| Reverse polarity protection | No — input voltage below –10 V can destroy the module |
| Module diagnosis | Yes |
| Individual channel diagnosis | Yes (outputs: overcurrent monitoring >0.5 A and line break detection; inputs: auxiliary voltage output only) |
| Galvanic isolation | 500 V DC between current paths |
| Supply voltage | 24 V DC +20% / –15%, via system bus |
| Current consumption from Isys, typ. | 8 mA |
| Current consumption from IIN | 8 mA |
| Current consumption from IOUT | 32 mA + load current |
| Type of connection | PUSH IN |
| Wire cross-section | 0.14 mm²–1.5 mm² (AWG 26–16), solid and finely stranded |
| Fieldbus protocols | PROFINET IRT/RT, PROFIBUS DP-V1, EtherCAT, Modbus/TCP, EtherNet/IP, CANopen, DeviceNet, POWERLINK, CC-Link, CC-Link IE TSN |
| Interface | u-remote system bus |
| Transmission speed, max. | 48 Mbit/s |
| Mounting | TS 35 DIN rail |
| Operating temperature | –20°C to +60°C |
| Storage temperature | –40°C to +85°C |
| Dimensions (W × H × D) | 11.5 mm × 120 mm × 76 mm |
| Net weight | 83 g |
| UL 94 flammability rating | V-0 |
| Pollution severity | 2 |
| Test voltage | 500 V |
| Surge voltage category | II |
| Vibration resistance | 5 Hz ≤ f ≤ 8.4 Hz: 3.5 mm amplitude; 8.4 Hz ≤ f ≤ 150 Hz: 1 g acceleration (IEC 60068-2-6) |
| Shock | 15 g over 11 ms, half sinus wave (IEC 60068-2-27) |
| RoHS compliance | Compliant with exemption (7a, 7cI) |
| REACH SVHC | Lead 7439-92-1, Diboron trioxide 1303-86-2, Lead monoxide 1317-36-8 |
| Product Carbon Footprint | 8.704 kg CO₂ eq. (cradle to gate) |
| Approvals / certifications | CE, UKCA, cULus (E141197), cULusEX (E223527), ATEX, IECEx, ClassNK, DNV, KR, RoHS compliant |
| Condition | New — in original packaging (OVP) |
Applications
- Flexible bidirectional signal handling in a single compact module — each of the 8 channels is configurable as a P-switching digital input (IEC 61131-2 Types 1 and 3) or a short-circuit-proof PNP output (up to 0.5 A), reducing the total module count needed in distributed u-remote I/O stations
- Enhanced output diagnostics with individual channel-level overcurrent monitoring (>0.5 A) and line break detection, enabling precise fault localisation without interrupting the rest of the module — critical for high-availability machine automation
- Robust actuator and sensor protection via a constant-current protective circuit with thermal switch-off and automatic restart, electronically limited sensor and actuator supply (≥0.3 A / ≤0.3 A per connector), and a <100 µs response time on the protective circuit
- Application-flexible input filtering with adjustable input delay from 0 to 40 ms, allowing the module to accommodate diverse sensor types and noise environments in 2- and 3-wire connection topologies
- Hazardous area installations (ATEX/IECEx) and marine applications requiring certified combined digital I/O modules with ClassNK, DNV, and KR approvals
Shipping
- Ships within 3 days after payment
- Secure packaging for safe industrial transport
- Free delivery within Germany
Warranty & compliance
- 12-month warranty included
- Product is fully compliant with EU industry standards
- VAT invoice included with every order
(GPSR (EU) 2023/988): Contact us at info@liquisto.com for Manufacturer / EU Responsible Party product safety contact details.