{"product_id":"weidmuller-ur20-16aux-fe","title":"Weidmüller UR20-16AUX-FE","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eWeidmüller UR20-16AUX-FE \/ Lenze W510-C-AX-001 — potential distribution module, 16-channel, PUSH IN, 24 V DC, IP20, u-remote system, order no. 1334790000. A potential distribution module for the u-remote system, providing 16 \"PUSH IN\" potential points for the supply of sensors with 2- to 4-wire connection technology directly from the remote I\/O system. The module loops through both the system bus and voltage supply, making it equally suited as an expansion slot placeholder — systems can be extended and started up without interruptions when required. Compatible with all u-remote fieldbus head stations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAvailable in stock\u003c\/strong\u003e — ships within 3 days after payment.\u003c\/p\u003e\n\u003ch3\u003eProduct overview\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 12px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eWeidmüller Interface GmbH \u0026amp; Co. KG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eUR20-16AUX-FE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eOrder number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e1334790000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eGTIN (EAN)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e4050118138085\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eSystem reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eLenze W510-C-AX-001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eRemote I\/O module, IP20, Potential distributor, PUSH IN connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eModule type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eAuxiliary module — potential distribution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eNumber of potential points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eType of connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003ePUSH IN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eWire cross-section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e0.14 mm²–1.5 mm² (AWG 26–16), solid and finely stranded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e24 V DC +20% \/ –15%, from input or output current path \/ FE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eGalvanic isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e500 V DC between the current paths\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eu-remote system bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eTransmission speed, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e48 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eFieldbus protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003ePROFINET IRT\/RT, PROFIBUS DP-V1, EtherCAT, Modbus\/TCP, EtherNet\/IP, CANopen, DeviceNet, POWERLINK, CC-Link, CC-Link IE TSN, IEC 61162-450\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eTS 35 DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e–20°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eStorage temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e–40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e11.5 mm × 120 mm × 76 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eMounting dimension – height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e128 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e84 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eUL 94 flammability rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eV-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003ePollution severity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eSurge voltage category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eVibration resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e5 Hz ≤ f ≤ 8.4 Hz: 3.5 mm amplitude; 8.4 Hz ≤ f ≤ 150 Hz: 1 g acceleration (IEC 60068-2-6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eShock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e15 g over 11 ms, half sinus wave (IEC 60068-2-27)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eAir humidity (operation\/storage\/transport)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e10% to 95%, non-condensing (DIN EN 61131-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eAir pressure (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e≥ 795 hPa (height ≤ 2000 m, DIN EN 61131-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eRoHS compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eCompliant with exemption (7a, 7cI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eREACH SVHC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eLead 7439-92-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eProduct Carbon Footprint\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e2.763 kg CO₂ eq. (cradle to gate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eApprovals \/ certifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eCE, UKCA, cULus (E141197), cULusEX (E223527), ATEX, IECEx, ClassNK, DNV, KR, ABS, KoreaCert, RoHS compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eNew — in original packaging (OVP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eFlexible sensor supply distribution for 2- to 4-wire field devices directly from the u-remote system, providing 16 PUSH IN potential points for any auxiliary potential required in machine and plant engineering\u003c\/li\u003e\n\u003cli\u003eExpansion slot planning — the looped-through system bus and voltage supply allow slots to be reserved in a station layout and activated without system interruption when the application grows\u003c\/li\u003e\n\u003cli\u003eUse alongside digital and analog I\/O modules to distribute 24 V DC sensor supply or reference potentials without additional terminal blocks or external distribution hardware\u003c\/li\u003e\n\u003cli\u003eHazardous area installations (ATEX\/IECEx) and marine applications requiring certified auxiliary modules with ABS, ClassNK, DNV, and KR approvals\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShipping\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eShips within 3 days after payment\u003c\/li\u003e\n\u003cli\u003eSecure packaging for safe industrial transport\u003c\/li\u003e\n\u003cli\u003eFree delivery within Germany\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty \u0026amp; compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e12-month warranty included\u003c\/li\u003e\n\u003cli\u003eProduct is fully compliant with EU industry standards\u003c\/li\u003e\n\u003cli\u003eVAT invoice included with every order\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e(GPSR (EU) 2023\/988): Contact us at \u003ca href=\"mailto:info@liquisto.com\"\u003einfo@liquisto.com\u003c\/a\u003e for Manufacturer \/ EU Responsible Party product safety contact details.\u003c\/p\u003e","brand":"WEIDMUELLER","offers":[{"title":"Default Title","offer_id":57783214407944,"sku":"LNZ-13642268","price":35.99,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/7566\/1973\/files\/WeidmullerUR20-16AUX-FE.jpg?v=1778513100","url":"https:\/\/liquistoaxcess.com\/en-eu\/products\/weidmuller-ur20-16aux-fe","provider":"LiquistoAxcess","version":"1.0","type":"link"}