Weidmüller UR20-4AI-TC-DIAG
Add to cart to view estimated shipping cost.
Weidmüller UR20-4AI-TC-DIAG / Lenze W540-C-2E-014 — 4-channel thermocouple analogue input module, 16-bit resolution, individual channel diagnosis, 50/60 Hz suppression, PUSH IN, IP20, u-remote system, order no. 1315710000. A 4-channel temperature input module for the u-remote system. With an accuracy of 0.2% FSR and 16-bit resolution, the module covers a measured temperature range from –200°C to +2315°C. Internal and external cold-junction compensation (internal accuracy ≤ 3 K) is provided, along with automatic 50 Hz to 60 Hz interference suppression. Cable break and out-of-range values are detected via individual channel diagnosis. The adjustable conversion time of 36 to 240 ms allows the module to be optimised for speed or accuracy. Sensors connect via 2-wire PUSH IN terminals. The module electronics supply connected sensors from the input current path (UIN). Compatible with all u-remote fieldbus head stations.
Available in stock — ships within 3 days after payment.
Product overview
| Manufacturer | Weidmüller Interface GmbH & Co. KG |
| Type | UR20-4AI-TC-DIAG |
| Order number | 1315710000 |
| GTIN (EAN) | 4050118118889 |
| System reference | Lenze W540-C-2E-014 |
| Product type | Remote I/O module, IP20, Analog signals, Temperature, TC, 4-channel, PUSH IN connection |
| Module type | Temperature module — 4-channel thermocouple input, 16-bit, diagnostics |
| Number of analogue inputs | 4 |
| Thermocouple types supported | J, K, T, B, N, E, R, S, L, U, C, mV |
| Resolution | 16 Bit |
| Accuracy | 0.2% FSR |
| Measured temperature range | –200°C to +2315°C |
| Cold junction compensation | Internal and external (internal accuracy ≤ 3 K) |
| Conversion time | Adjustable, 36…240 ms |
| Temperature coefficient | ≤ 50 ppm/K |
| Internal resistance U | 1 MΩ |
| Reverse polarity protection | Yes |
| Module diagnosis | Yes |
| Individual channel diagnosis | Yes |
| Sensor connection | 2-wire |
| Process data | 8 Byte |
| Parameter data | 32 Byte |
| Diagnostic data | 20 Byte |
| Supply voltage | 24 V DC +20% / –15%, via system bus |
| Current consumption from Isys, typ. | 8 mA |
| Current consumption from IIN | <20 mA |
| Galvanic isolation | 500 V DC between the current paths |
| Type of connection | PUSH IN |
| Wire cross-section | 0.14 mm²–1.5 mm² (AWG 26–16), solid and finely stranded |
| Fieldbus protocols | PROFINET IRT/RT, PROFIBUS DP-V1, EtherCAT, Modbus/TCP, EtherNet/IP, CANopen, DeviceNet, POWERLINK |
| Interface | u-remote system bus |
| Transmission speed, max. | 48 Mbit/s |
| Mounting | TS 35 DIN rail |
| Operating temperature | –20°C to +60°C |
| Storage temperature | –40°C to +85°C |
| Dimensions (W × H × D) | 11.5 mm × 120 mm × 76 mm |
| Mounting dimension – height | 128 mm |
| Net weight | 86 g |
| UL 94 flammability rating | V-0 |
| Pollution severity | 2 |
| Test voltage | 500 V |
| Surge voltage category | II |
| Vibration resistance | 5 Hz ≤ f ≤ 8.4 Hz: 3.5 mm amplitude; 8.4 Hz ≤ f ≤ 150 Hz: 1 g acceleration (IEC 60068-2-6) |
| Shock | 15 g over 11 ms, half sinus wave (IEC 60068-2-27) |
| Air humidity (operation/storage/transport) | 10% to 95%, non-condensing (DIN EN 61131-2) |
| Air pressure (operation) | ≥ 795 hPa (height ≤ 2000 m, DIN EN 61131-2) |
| RoHS compliance | Compliant with exemption (7a, 7cI) |
| REACH SVHC | Lead 7439-92-1 |
| Product Carbon Footprint | 8.684 kg CO₂ eq. (cradle to gate) |
| Approvals / certifications | CE, UKCA, cULus (E141197), cULusEX (E223527), ATEX, IECEx, ClassNK, ABS, DNV, KoreaCert, RoHS compliant |
| Condition | New — in original packaging (OVP) |
Applications
- Multi-type thermocouple temperature measurement in machine and plant engineering — a single module accepts all common thermocouple types (J, K, T, B, N, E, R, S, L, U, C) as well as direct millivolt signals across a measurement range of –200°C to +2315°C, eliminating the need for separate modules for different thermocouple types in mixed-sensor installations such as furnaces, dryers, extruders and heat treatment systems
- High-accuracy temperature acquisition with cable break detection — 16-bit resolution, 0.2% FSR accuracy and individual channel diagnosis with cable break and over/under-range detection enable reliable, precise temperature monitoring with immediate fault notification down to the channel level, supporting preventive maintenance and process safety in critical thermal applications
- Suppression of mains interference in industrial environments — automatic 50 Hz to 60 Hz interference suppression eliminates the dominant noise source in AC-powered installations, ensuring clean thermocouple signal acquisition even when sensor cables run close to power wiring, variable frequency drives or other noise-generating equipment
- Flexible cold-junction compensation for accurate absolute temperature readings — both internal cold-junction compensation (accuracy ≤ 3 K) and external cold-junction compensation are supported, allowing the module to be configured for applications where terminal block temperature variations must be precisely compensated to achieve accurate absolute temperature measurement
- Hazardous area and marine temperature monitoring — ATEX, IECEx, ClassNK, ABS and DNV certifications alongside reverse polarity protection make this module suitable for certified thermocouple temperature acquisition in offshore, marine and Ex-zone environments within mixed u-remote I/O stations compatible with PROFINET, EtherCAT, PROFIBUS, Modbus/TCP, EtherNet/IP and other supported fieldbus protocols
Shipping
- Ships within 3 days after payment
- Secure packaging for safe industrial transport
- Free delivery within Germany
Warranty & compliance
- 12-month warranty included
- Product is fully compliant with EU industry standards
- VAT invoice included with every order
(GPSR (EU) 2023/988): Contact us at info@liquisto.com for Manufacturer / EU Responsible Party product safety contact details.