Weidmüller UR20-4DO-P-2A
Add to cart to view estimated shipping cost.
Weidmüller UR20-4DO-P-2A / Lenze W560-C-2A-005 — digital output module, 4-channel, P-switching, 2 A per channel, 24 V DC, PUSH IN, IP20, u-remote system, order no. 1315230000. A 4-channel P-switching digital output module for the u-remote system, designed for the incorporation of decentralised actuators with a high per-channel output current of up to 2000 mA. All outputs support lamp, ohmic, and inductive load types per DIN EN 60947-5-1 and IEC 61131-2 specifications, with a maximum module output current of 8000 mA and a 100% simultaneity factor. The module electronics supply the connected actuators from the output current path (UOUT). Compatible with all u-remote fieldbus head stations.
Available in stock — ships within 3 days after payment.
Product overview
| Manufacturer | Weidmüller Interface GmbH & Co. KG |
| Type | UR20-4DO-P-2A |
| Order number | 1315230000 |
| GTIN (EAN) | 4050118118377 |
| System reference | Lenze W560-C-2A-005 |
| Product type | Remote I/O module, IP20, Digital signals, Output, 4-channel, 2 A per channel, PUSH IN connection |
| Module type | Digital output module — 4-channel, P-switching, 2 A per channel |
| Number of digital outputs | 4 |
| Output type | Lamp load, Ohmic, Inductive |
| Output current per channel, max. | 2000 mA |
| Output current per module, max. | 8000 mA |
| Output current as per application | min. 0 mA, nominal 8000 mA, max. 8000 mA |
| Simultaneity factor | min. 0%, nominal 100%, max. 100% |
| Leakage current | <0.3 mA |
| Max. response time, high | 100 µs |
| Max. response time, low | 250 µs |
| Response time of protective circuit | <100 µs (current limiting) |
| Short-circuit protection | Yes — thermal cut-out with automatic restart |
| Switch-off energy (inductive) | <150 mJ / channel |
| Resistive load (min. 47 Ω) | 1 kHz |
| Lamp load (12 W) | 1 kHz |
| Inductive load (DC13) | 0.2 Hz |
| Feedback-free | Yes |
| Module diagnosis | Yes |
| Individual channel diagnosis | No |
| Actuator connection | 2-wire, 3-wire, 3-wire + FE |
| Actuator supply, max. | 750 mA |
| Process data | 4 Bit |
| Diagnostic data | 1 Bit |
| Supply voltage | 24 V DC +20% / –15%, via system bus |
| Current consumption from Isys, typ. | 8 mA |
| Current consumption from IOUT | 10 mA + load |
| Galvanic isolation | 500 V DC between the current paths |
| Type of connection | PUSH IN |
| Wire cross-section | 0.14 mm²–1.5 mm² (AWG 26–16), solid and finely stranded |
| Fieldbus protocols | PROFINET IRT/RT, PROFIBUS DP-V1, EtherCAT, Modbus/TCP, EtherNet/IP, CANopen, DeviceNet, POWERLINK, CC-Link, CC-Link IE TSN, IEC 61162-450 |
| Interface | u-remote system bus |
| Transmission speed, max. | 48 Mbit/s |
| Mounting | TS 35 DIN rail |
| Operating temperature | –20°C to +60°C |
| Storage temperature | –40°C to +85°C |
| Dimensions (W × H × D) | 11.5 mm × 120 mm × 76 mm |
| Mounting dimension – height | 128 mm |
| Net weight | 85 g |
| UL 94 flammability rating | V-0 |
| Pollution severity | 2 |
| Test voltage | 500 V |
| Surge voltage category | II |
| Vibration resistance | 5 Hz ≤ f ≤ 8.4 Hz: 3.5 mm amplitude; 8.4 Hz ≤ f ≤ 150 Hz: 1 g acceleration (IEC 60068-2-6) |
| Shock | 15 g over 11 ms, half sinus wave (IEC 60068-2-27) |
| Air humidity (operation/storage/transport) | 10% to 95%, non-condensing (DIN EN 61131-2) |
| Air pressure (operation) | ≥ 795 hPa (height ≤ 2000 m, DIN EN 61131-2) |
| RoHS compliance | Compliant with exemption (7a, 7cI) |
| REACH SVHC | Lead 7439-92-1 |
| Product Carbon Footprint | 8.684 kg CO₂ eq. (cradle to gate) |
| Approvals / certifications | CE, UKCA, cULus (E141197), cULusEX (E223527), ATEX, IECEx, ClassNK, DNV, KR, ABS, KoreaCert, RoHS compliant |
| Condition | New — in original packaging (OVP) |
Applications
- High-current decentralised actuator control for power-hungry field devices — 4 P-switching outputs each delivering up to 2000 mA drive solenoid valves, motor starters, heavy-duty indicator lamps, and other DC-13 loads per DIN EN 60947-5-1 and IEC 61131-2 with a full 100% simultaneity factor
- Mixed load applications requiring a single output module to handle lamp, ohmic, and inductive loads — the thermal cut-out short-circuit protection with automatic restart and inductive switch-off energy limiting (<150 mJ/channel) protect both the module and connected field devices
- Flexible actuator wiring in 2-wire, 3-wire, and 3-wire + FE topologies with an integrated actuator supply of up to 750 mA, reducing the need for separate power distribution components in the u-remote station
- Switching applications up to 1 kHz for resistive and lamp loads, with module-level diagnostics and clearly visible per-channel LEDs for fast fault identification during commissioning and maintenance
- Hazardous area installations (ATEX/IECEx) and marine applications requiring certified digital output modules with ABS, ClassNK, DNV, and KR approvals
Shipping
- Ships within 3 days after payment
- Secure packaging for safe industrial transport
- Free delivery within Germany
Warranty & compliance
- 12-month warranty included
- Product is fully compliant with EU industry standards
- VAT invoice included with every order
(GPSR (EU) 2023/988): Contact us at info@liquisto.com for Manufacturer / EU Responsible Party product safety contact details.