{"product_id":"weidmuller-ur20-2ai-sg-24-diag","title":"Weidmüller UR20-2AI-SG-24-DIAG","description":"\u003cp\u003eWeidmüller UR20-2AI-SG-24-DIAG \/ Lenze W540-C-1E-003 — 2-channel analogue input module for strain gauge and load cell analysis, 24-bit resolution, PUSH IN, IP20, u-remote system, order no. 1990070000. A 2-channel module for u-remote load cell analysis, designed for measuring bridges in the form of strain gauges to measure weight, torque or oscillation. The module delivers an accuracy of up to 0.01% FSR (100 ppm) with two 24-bit resolution channels and a parameterisable conversion time of 5–800 ms. Up to four load cells can be analysed in parallel on a single channel. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAvailable in stock\u003c\/strong\u003e — ships within 3 days after payment.\u003c\/p\u003e\n\u003ch3\u003eProduct overview\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 12px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eWeidmüller Interface GmbH \u0026amp; Co. KG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eUR20-2AI-SG-24-DIAG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eOrder number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e1990070000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eGTIN (EAN)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e4050118374902\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eSystem reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eLenze W540-C-1E-003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eRemote I\/O module, IP20, Analog signals, Input, 2-channel, PUSH IN connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eModule type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eAnalogue input module — 2-channel, strain gauge, 24-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eNumber of analogue inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e24 bit per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eCustomer calibration: ±0.01% FSR (100 ppm), ±1% FSR (with interference)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eMeasurement range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e± 150 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eInput value\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eDifferential, to evaluate a strain gauge full-bridge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eConversion time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e5 – 800 ms, parameterisable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eTemperature coefficient\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e\u0026lt;5 ppm\/K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eInput filter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eInput type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eType 1 in acc. with IEC 61131-2, Type 3 in acc. with IEC 61131-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003ePermissible sensor load\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e85 … 5000 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eSupported sensor sensitivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e0.5 mV – 30 V, parameterisable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eSensor supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003enominal 10 mA, max. 10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eSensor connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e4-wire, 6-wire, parameterisable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eShort-circuit-proof\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eModule diagnosis\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eIndividual channel diagnosis\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eNumber of digital inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eInput voltage, high\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e\u0026gt; 11 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eInput voltage, low\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e\u0026lt; 5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eProcess data\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e10 Byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eParameter data\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e14 Byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eDiagnostic data\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e1 Bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e24 V DC +20% \/ –15%, via system bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eCurrent consumption from Isys, typ.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e8 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eCurrent consumption from IIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e35 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eGalvanic isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e500 V DC between the current paths\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eConfiguration interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eMicro USB 2.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eType of connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003ePUSH IN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eWire cross-section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e0.14 mm²–1.5 mm² (AWG 26–16), solid and finely stranded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eFieldbus protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003ePROFINET IRT\/RT, PROFIBUS DP-V1, EtherCAT, Modbus\/TCP, EtherNet\/IP, CANopen, DeviceNet, POWERLINK, CC-Link, CC-Link IE TSN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eu-remote system bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eTransmission speed, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e48 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eTS 35 DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e–20°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eStorage temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e–40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e11.5 mm × 120 mm × 76 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eMounting dimension – height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e128 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e90 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eUL 94 flammability rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eV-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003ePollution severity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eSurge voltage category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eVibration resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e5 Hz ≤ f ≤ 8.4 Hz: 3.5 mm amplitude; 8.4 Hz ≤ f ≤ 150 Hz: 1 g acceleration (IEC 60068-2-6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eShock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e15 g over 11 ms, half sinus wave (IEC 60068-2-27)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eAir humidity (operation\/storage\/transport)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e10% to 95%, non-condensing (DIN EN 61131-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eAir pressure (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e≥ 795 hPa (height ≤ 2000 m, DIN EN 61131-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eRoHS compliance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eCompliant with exemption (7a, 7cI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eREACH SVHC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eLead 7439-92-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eProduct Carbon Footprint\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e8.848 kg CO₂ eq. (cradle to gate)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eApprovals \/ certifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eCE, UKCA, cULus (E141197), cULusEX (E223527), ATEX, IECEx, KoreaCert, RoHS compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eNew — in original packaging (OVP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePrecision weight, torque and oscillation measurement using strain gauge full-bridge configurations — with 24-bit resolution per channel and an accuracy of up to ±0.01% FSR (100 ppm) after customer calibration, the module is suited to demanding industrial weighing, force measurement and process control applications requiring high-resolution analogue data acquisition\u003c\/li\u003e\n\u003cli\u003eMulti-load-cell installations — up to four load cells can be analysed in parallel on a single channel, reducing module count and cabinet space in scales, press monitoring systems and conveyor weighing applications while maintaining full measurement integrity\u003c\/li\u003e\n\u003cli\u003eApplications requiring traceable calibration and audit trails — independent calibration body access via the u-remote web server, with password protection and documentation functionality, enables legal-for-trade and quality-assured weighing installations compliant with industrial calibration and gauging requirements\u003c\/li\u003e\n\u003cli\u003eProcess optimisation with tare functionality — a per-channel tare function can be triggered during operation, making the module well-suited to batching, filling and dosing systems where zeroing under load is required without interrupting the production process\u003c\/li\u003e\n\u003cli\u003eHazardous area and mixed I\/O installations — with ATEX\/IECEx certification and compatibility with all u-remote fieldbus head stations across PROFINET, EtherCAT, PROFIBUS, Modbus\/TCP, EtherNet\/IP and other protocols, the module integrates seamlessly into safety-rated and standard u-remote stations alongside digital and other analogue modules\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShipping\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eShips within 3 days after payment\u003c\/li\u003e\n\u003cli\u003eSecure packaging for safe industrial transport\u003c\/li\u003e\n\u003cli\u003eFree delivery within Germany\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty \u0026amp; compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e12-month warranty included\u003c\/li\u003e\n\u003cli\u003eProduct is fully compliant with EU industry standards\u003c\/li\u003e\n\u003cli\u003eVAT invoice included with every order\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e(GPSR (EU) 2023\/988): Contact us at \u003ca href=\"mailto:info@liquisto.com\"\u003einfo@liquisto.com\u003c\/a\u003e for Manufacturer \/ EU Responsible Party product safety contact details.\u003c\/p\u003e","brand":"WEIDMUELLER","offers":[{"title":"Default Title","offer_id":57779160776968,"sku":"LNZ-13642285","price":257.99,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/7566\/1973\/files\/WeidmullerUR20-2AI-SG-24-DIAG.jpg?v=1778527763","url":"https:\/\/liquistoaxcess.com\/nl-eu\/products\/weidmuller-ur20-2ai-sg-24-diag","provider":"LiquistoAxcess","version":"1.0","type":"link"}