{"product_id":"weidmuller-ur20-4ai-ui-16-diag-hd","title":"Weidmüller UR20-4AI-UI-16-DIAG-HD","description":"\u003cp\u003eWeidmüller UR20-4AI-UI-16-DIAG-HD \/ Lenze W540-C-2E-006 — 4-channel analogue input module for current and voltage signals, 16-bit resolution, PUSH IN, IP20, u-remote system, order no. 1506910000. A 4-channel module for the u-remote system. Each plug-in connector optionally supports 2-wire or 3-wire sensor technology, and the measurement range can be individually parameterised per channel. Each channel features its own status LED. Both module and individual channel diagnosis are supported. The module electronics supply the connected sensors with power from the input current path (UIN). Compatible with all u-remote fieldbus head stations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAvailable in stock\u003c\/strong\u003e — ships within 3 days after payment.\u003c\/p\u003e\n\u003ch3\u003eProduct overview\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 12px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eWeidmüller Interface GmbH \u0026amp; Co. KG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eUR20-4AI-UI-16-DIAG-HD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eOrder number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e1506910000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eGTIN (EAN)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e4050118315417\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eSystem reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eLenze W540-C-2E-006\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eRemote I\/O module, IP20, Analog signals, Input, 4-channel, PUSH IN connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eModule type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eAnalogue input module — 4-channel, current\/voltage, 16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eNumber of analogue inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e16 Bit per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e0.1% FSR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eInput type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e1. U (0…5 V, 0…10 V, 1…5 V, 2…10 V, ±10 V), 2. I (0–20 mA or 4–20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eConversion time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eInternal resistance (voltage)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eInternal resistance (current)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e45 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eSensor connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e2-wire, 3-wire, 3-wire + FE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eSensor supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eYes — 25 mA + sensor feed (from IIN power segment)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eModule diagnosis\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eIndividual channel diagnosis\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eProcess data\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e8 Byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eDiagnostic data\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e1 Bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e24 V DC +20% \/ –15%, via system bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eCurrent consumption from Isys, typ.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e8 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eCurrent consumption from IIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e25 mA + sensor feed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eGalvanic isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e500 V DC between the current paths\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eType of connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003ePUSH IN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eWire cross-section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e0.14 mm²–0.35 mm² (AWG 26–22), solid and finely stranded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eFieldbus protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003ePROFINET IRT\/RT, PROFIBUS DP-V1, EtherCAT, Modbus\/TCP, EtherNet\/IP, CANopen, DeviceNet, POWERLINK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eu-remote system bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eTS 35 DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e–20°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eStorage temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e–40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e11.5 mm × 120 mm × 76 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eMounting dimension – height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e128 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e72 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eUL 94 flammability rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eV-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003ePollution severity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eSurge voltage category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eVibration resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e5 Hz ≤ f ≤ 8.4 Hz: 3.5 mm amplitude; 8.4 Hz ≤ f ≤ 150 Hz: 1 g acceleration (IEC 60068-2-6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eShock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e15 g over 11 ms, half sinus wave (IEC 60068-2-27)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eAir humidity (operation\/storage\/transport)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e10% to 95%, non-condensing (DIN EN 61131-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eAir pressure (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e≥ 795 hPa (height ≤ 2000 m, DIN EN 61131-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eREACH SVHC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eLead 7439-92-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eApprovals \/ certifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eCE, UKCA, cULus, cULusEX, ATEX, IECEx, KoreaCert, RoHS compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eNew — in original packaging (OVP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-accuracy analogue signal acquisition with per-channel diagnostics — with 16-bit resolution and 0.1% FSR accuracy across four channels, combined with individual channel diagnosis, the module is suited to demanding industrial process monitoring and control applications where both measurement precision and fault detection at channel level are required\u003c\/li\u003e\n\u003cli\u003eMulti-sensor installations with flexible wiring options — each of the four channels supports 2-wire or 3-wire sensor connection (including functional earth), with individually parameterisable measurement ranges per channel, making the module well-suited to mixed-sensor cabinet installations and distributed I\/O applications handling voltage and current signals simultaneously\u003c\/li\u003e\n\u003cli\u003eApplications requiring fast signal conversion — with a conversion time of 1 ms, the module is appropriate for dynamic process control tasks where timely analogue value updates are critical, such as closed-loop feedback systems, drive control and real-time process regulation\u003c\/li\u003e\n\u003cli\u003eSensor-powered installations — the module supplies connected sensors directly from the input current path (UIN), eliminating the need for separate sensor power supplies in many standard 2- and 3-wire transducer installations, simplifying cabinet design and reducing wiring effort\u003c\/li\u003e\n\u003cli\u003eMixed I\/O and multi-protocol installations — compatible with all u-remote fieldbus head stations across PROFINET, EtherCAT, PROFIBUS DP-V1, Modbus\/TCP, EtherNet\/IP, CANopen, DeviceNet and POWERLINK, the module integrates seamlessly alongside digital and other analogue u-remote modules in both standard and ATEX\/IECEx-rated stations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShipping\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eShips within 3 days after payment\u003c\/li\u003e\n\u003cli\u003eSecure packaging for safe industrial transport\u003c\/li\u003e\n\u003cli\u003eFree delivery within Germany\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty \u0026amp; compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e12-month warranty included\u003c\/li\u003e\n\u003cli\u003eProduct is fully compliant with EU industry standards\u003c\/li\u003e\n\u003cli\u003eVAT invoice included with every order\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e(GPSR (EU) 2023\/988): Contact us at \u003ca href=\"mailto:info@liquisto.com\"\u003einfo@liquisto.com\u003c\/a\u003e for Manufacturer \/ EU Responsible Party product safety contact details.\u003c\/p\u003e","brand":"WEIDMUELLER","offers":[{"title":"Default Title","offer_id":57784946983176,"sku":"LNZ-13642291","price":286.79,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/7566\/1973\/files\/Weidm_ller_UR20-4AI-UI-16-DIAG-HD.png?v=1778572436","url":"https:\/\/liquistoaxcess.com\/pt-eu\/products\/weidmuller-ur20-4ai-ui-16-diag-hd","provider":"LiquistoAxcess","version":"1.0","type":"link"}