{"product_id":"weidmuller-ur20-4ai-ui-16-hd","title":"Weidmüller UR20-4AI-UI-16-HD","description":"\u003cp\u003eWeidmüller UR20-4AI-UI-16-HD \/ Lenze W540-C-2E-007 — 4-channel analogue input module for current and voltage signals, 16-bit resolution, PUSH IN, IP20, u-remote system, order no. 1506920000. A 4-channel module for the u-remote system. The module delivers an accuracy of 0.1% FSR with 16-bit resolution per channel and a conversion time of 1 ms. Each plug-in connector optionally supports 2-wire or 3-wire sensor technology, and the measurement range can be individually parameterised per channel. Each channel features its own status LED. The module electronics supply the connected sensors with power from the input current path (UIN). Module-level diagnosis is supported. Compatible with all u-remote fieldbus head stations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAvailable in stock\u003c\/strong\u003e — ships within 3 days after payment.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eNote: Please order connector (1469340000) separately.\u003c\/em\u003e\u003c\/p\u003e\n\u003ch3\u003eProduct overview\u003c\/h3\u003e\n\u003ctable style=\"width: 100%; border-collapse: collapse; font-size: 12px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eWeidmüller Interface GmbH \u0026amp; Co. KG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eType\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eUR20-4AI-UI-16-HD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eOrder number\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e1506920000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eGTIN (EAN)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e4050118315424\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eSystem reference\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eLenze W540-C-2E-007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eProduct type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eRemote I\/O module, IP20, Analog signals, Input, 4-channel, PUSH IN connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eModule type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eAnalogue input module — 4-channel, current\/voltage, 16-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eNumber of analogue inputs\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eResolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e16 Bit per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eAccuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e0.1% FSR\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eInput type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e1. U (0…5 V, 0…10 V, 1…5 V, 2…10 V, ±10 V), 2. I (0–20 mA or 4–20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eConversion time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eResponse time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e\u0026lt; 50 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eInternal resistance (voltage)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e100 kΩ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eInternal resistance (current)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e45 Ω\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eSensor connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e2-wire, 3-wire, 3-wire + FE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eSensor supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eYes — nominal 750 mA, max. 750 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eShort-circuit-proof\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eReverse polarity protection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eModule diagnosis\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eIndividual channel diagnosis\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eProcess data\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e8 Byte\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eDiagnostic data\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e1 Bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eSupply voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e24 V DC +20% \/ –15%, via system bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eCurrent consumption from Isys, typ.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e8 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eCurrent consumption from IIN\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e25 mA + sensor feed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eGalvanic isolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e500 V DC between the current paths\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eType of connection\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003ePUSH IN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eWire cross-section\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e0.14 mm²–0.35 mm² (AWG 26–22), solid and finely stranded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eFieldbus protocols\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003ePROFINET IRT\/RT, PROFIBUS DP-V1, EtherCAT, Modbus\/TCP, EtherNet\/IP, CANopen, DeviceNet, POWERLINK, CC-Link, CC-Link IE TSN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eInterface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eu-remote system bus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eTransmission speed, max.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e48 Mbit\/s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eTS 35 DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e–20°C to +60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eStorage temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e–40°C to +85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eDimensions (W × H × D)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e11.5 mm × 120 mm × 76 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eMounting dimension – height\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e128 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eNet weight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e72 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eUL 94 flammability rating\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eV-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003ePollution severity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eSurge voltage category\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eVibration resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e5 Hz ≤ f ≤ 8.4 Hz: 3.5 mm amplitude; 8.4 Hz ≤ f ≤ 150 Hz: 1 g acceleration (IEC 60068-2-6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eShock\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e15 g over 11 ms, half sinus wave (IEC 60068-2-27)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eAir humidity (operation\/storage\/transport)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e10% to 95%, non-condensing (DIN EN 61131-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eAir pressure (operation)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003e≥ 795 hPa (height ≤ 2000 m, DIN EN 61131-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eREACH SVHC\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eLead 7439-92-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eApprovals \/ certifications\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eCE, UKCA, cULus (E141197), cULusEX (E223527), ATEX, IECEx, KoreaCert, RoHS compliant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"padding: 6px 8px; width: 40%;\"\u003e\u003cstrong\u003eCondition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"padding: 6px 8px;\"\u003eNew — in original packaging (OVP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eApplications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-accuracy analogue signal acquisition for voltage and current sensors — with 16-bit resolution per channel and an accuracy of 0.1% FSR, the module is suited to industrial process monitoring, control loop feedback and measurement applications requiring precise analogue data from sensors outputting ±10 V, 0…10 V, 1…5 V, 2…10 V, 0…20 mA or 4…20 mA signals\u003c\/li\u003e\n\u003cli\u003eMulti-sensor installations with flexible wiring options — each of the four channels supports 2-wire or 3-wire sensor connection (including functional earth), with individually parameterisable measurement ranges per channel, making the module well-suited to mixed-sensor cabinet installations and distributed I\/O applications\u003c\/li\u003e\n\u003cli\u003eApplications requiring fast signal conversion — with a conversion time of 1 ms and a response time of less than 50 ms, the module is appropriate for dynamic process control tasks where timely analogue value updates are critical to system performance\u003c\/li\u003e\n\u003cli\u003eSensor-powered installations — the module supplies connected sensors directly from the input current path (UIN) with up to 750 mA, eliminating the need for separate sensor power supplies in many standard 2- and 3-wire transducer installations\u003c\/li\u003e\n\u003cli\u003eMixed I\/O and multi-protocol installations — compatible with all u-remote fieldbus head stations across PROFINET, EtherCAT, PROFIBUS, Modbus\/TCP, EtherNet\/IP, CANopen, DeviceNet, POWERLINK, CC-Link and CC-Link IE TSN, the module integrates seamlessly alongside digital and other analogue u-remote modules in both standard and ATEX\/IECEx-rated stations\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eShipping\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eShips within 3 days after payment\u003c\/li\u003e\n\u003cli\u003eSecure packaging for safe industrial transport\u003c\/li\u003e\n\u003cli\u003eFree delivery within Germany\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eWarranty \u0026amp; compliance\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e12-month warranty included\u003c\/li\u003e\n\u003cli\u003eProduct is fully compliant with EU industry standards\u003c\/li\u003e\n\u003cli\u003eVAT invoice included with every order\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e(GPSR (EU) 2023\/988): Contact us at \u003ca href=\"mailto:info@liquisto.com\"\u003einfo@liquisto.com\u003c\/a\u003e for Manufacturer \/ EU Responsible Party product safety contact details.\u003c\/p\u003e","brand":"WEIDMUELLER","offers":[{"title":"Default Title","offer_id":57785314738440,"sku":"LNZ-13642292","price":239.99,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0574\/7566\/1973\/files\/UR20-4AI-UI-16-HD.png?v=1778572316","url":"https:\/\/liquistoaxcess.com\/sl-eu\/products\/weidmuller-ur20-4ai-ui-16-hd","provider":"LiquistoAxcess","version":"1.0","type":"link"}