Weidmüller UR20-4AI-RTD-DIAG
Add to cart to view estimated shipping cost.
Weidmüller UR20-4AI-RTD-DIAG / Lenze W540-C-2E-012 — 4-channel RTD analogue input module, resistance temperature detector, 16-bit resolution, individual channel diagnosis, 50/60 Hz suppression, PUSH IN, IP20, u-remote system, order no. 1315700000. A 4-channel temperature input module for the u-remote system, the module detects cable breaks and over/under-range values via individual channel diagnosis. Automatic 50 Hz to 60 Hz interference suppression and an adjustable conversion time of 36 to 240 ms are included. Sensors connect via 2-wire, 3-wire or 4-wire PUSH IN terminals to support a wide range of RTD wiring configurations. The module electronics supply connected sensors from the input current path (UIN). Compatible with all u-remote fieldbus head stations.
Available in stock — ships within 3 days after payment.
Product overview
| Manufacturer | Weidmüller Interface GmbH & Co. KG |
| Type | UR20-4AI-RTD-DIAG |
| Order number | 1315700000 |
| GTIN (EAN) | 4050118118872 |
| System reference | Lenze W540-C-2E-012 |
| Product type | Remote I/O module, IP20, Analog signals, Temperature, RTD, 4-channel, PUSH IN connection |
| Module type | Temperature module — 4-channel RTD input, 16-bit, diagnostics |
| Number of analogue inputs | 4 |
| RTD types supported | Pt100, Pt200, Pt500, Pt1000, Ni100, Ni120, Ni200, Ni500, Ni1000, Cu10, 40 Ω, 80 Ω, 150 Ω, 300 Ω, 500 Ω, 1 kΩ, 2 kΩ, 4 kΩ |
| Resolution | 16 Bit |
| Accuracy | 0.2% FSR / 0.3% FSR for Ni sensors / 0.6% FSR for Cu10 |
| Measured temperature range | –200°C to +850°C |
| Conversion time | Adjustable, 36…240 ms |
| Temperature coefficient | ≤ 50 ppm/K |
| Internal resistance U | 1 MΩ |
| Reverse polarity protection | Yes |
| Module diagnosis | Yes |
| Individual channel diagnosis | Yes |
| Sensor connection | 2-wire, 3-wire, 4-wire |
| Process data | 8 Byte |
| Parameter data | 32 Byte |
| Diagnostic data | 20 Byte |
| Supply voltage | 24 V DC +20% / –15%, via system bus |
| Current consumption from Isys, typ. | 8 mA |
| Current consumption from IIN | <20 mA |
| Galvanic isolation | 500 V DC between the current paths |
| Type of connection | PUSH IN |
| Wire cross-section | 0.14 mm²–1.5 mm² (AWG 26–16), solid and finely stranded |
| Fieldbus protocols | PROFINET IRT/RT, PROFIBUS DP-V1, EtherCAT, Modbus/TCP, EtherNet/IP, CANopen, DeviceNet, POWERLINK |
| Interface | u-remote system bus |
| Transmission speed, max. | 48 Mbit/s |
| Mounting | TS 35 DIN rail |
| Operating temperature | –20°C to +60°C |
| Storage temperature | –40°C to +85°C |
| Dimensions (W × H × D) | 11.5 mm × 120 mm × 76 mm |
| Mounting dimension – height | 128 mm |
| Net weight | 91 g |
| UL 94 flammability rating | V-0 |
| Pollution severity | 2 |
| Test voltage | 500 V |
| Surge voltage category | II |
| Vibration resistance | 5 Hz ≤ f ≤ 8.4 Hz: 3.5 mm amplitude; 8.4 Hz ≤ f ≤ 150 Hz: 1 g acceleration (IEC 60068-2-6) |
| Shock | 15 g over 11 ms, half sinus wave (IEC 60068-2-27) |
| Air humidity (operation/storage/transport) | 10% to 95%, non-condensing (DIN EN 61131-2) |
| Air pressure (operation) | ≥ 795 hPa (height ≤ 2000 m, DIN EN 61131-2) |
| RoHS compliance | Compliant with exemption (7a, 7cI) |
| REACH SVHC | Lead 7439-92-1 |
| Product Carbon Footprint | 8.684 kg CO₂ eq. (cradle to gate) |
| Approvals / certifications | CE, UKCA, cULus (E141197), cULusEX (E223527), ATEX, IECEx, ClassNK, ABS, DNV, KoreaCert, RoHS compliant |
| Condition | New — in original packaging (OVP) |
Applications
- Multi-type RTD temperature measurement in machine and plant engineering — a single module accepts all common Pt, Ni and Cu resistance temperature detector types as well as fixed resistance inputs from 40 Ω to 4 kΩ across a measurement range of –200°C to +850°C, eliminating the need for separate modules for different RTD families in mixed-sensor installations such as motor windings, HVAC systems, food processing equipment and pharmaceutical processes
- High-accuracy temperature acquisition with 2-, 3- and 4-wire lead compensation — 16-bit resolution and 0.2% FSR accuracy for Pt sensors are combined with selectable 2-wire, 3-wire and 4-wire connection modes, allowing lead resistance errors to be fully compensated in 3- and 4-wire configurations for precise absolute temperature measurement over long cable runs
- Cable break and out-of-range detection via individual channel diagnosis — each channel independently monitors sensor integrity and measurement limits, providing 20 bytes of diagnostic data that enable rapid fault localisation down to the channel level without interrupting other channels, supporting high-availability process monitoring applications
- Suppression of mains interference in AC-powered installations — automatic 50 Hz to 60 Hz interference suppression eliminates the dominant AC noise source from RTD signal paths, ensuring stable and accurate temperature readings even when sensor wiring runs close to power cables, frequency inverters or switchgear in industrial cabinets
- Hazardous area and marine temperature monitoring — ATEX, IECEx, ClassNK, ABS and DNV certifications alongside reverse polarity protection make the module suitable for certified RTD temperature acquisition in offshore, marine and Ex-zone environments within mixed u-remote I/O stations compatible with PROFINET, EtherCAT, PROFIBUS, Modbus/TCP, EtherNet/IP and other supported fieldbus protocols
Shipping
- Ships within 3 days after payment
- Secure packaging for safe industrial transport
- Free delivery within Germany
Warranty & compliance
- 12-month warranty included
- Product is fully compliant with EU industry standards
- VAT invoice included with every order
(GPSR (EU) 2023/988): Contact us at info@liquisto.com for Manufacturer / EU Responsible Party product safety contact details.